Все 6 дата-центров работают

Оплата в криптовалюте · Без проверки личности · Root-доступ через менее 5 минут

Серьёзный Устранено

Core switch line-card failure in REY, row B

Сеть — транзит и пиринг — REY · Внеполосное управление — REY

Хронология

  1. Устранено

    Every machine in row B has been reachable since 22:22 UTC. Duration of the outage: 54 minutes. The failed card is being replaced under an existing maintenance window; the replacement does not require another interruption. Affected machines receive the SLA extension automatically.

  2. Наблюдение

    All 14 affected ports are up on the surviving card. We are checking each machine individually before closing this.

  3. Причина установлена

    A line card in one of the two core switches in REY failed. Row B was dual-homed, but the failover on 14 ports did not complete because the standby links were still training. We are forcing those ports over to the surviving card.

  4. Идёт расследование

    Machines in row B of REY lost network connectivity at 21:28 UTC. Rows outside B are unaffected. Engineers are on the floor.

Разбор инцидента публикуется здесь в течение пяти дней после устранения.

Войти

Консоль, инвойсы и внеполосный доступ.

Ещё нет аккаунта?

Отдельной регистрации нет. Ваш аккаунт создаётся, когда вы оформляете первый заказ — email и пароль вы указываете на шаге оплаты, и консоль открыта уже к моменту готовности машины.

Настроить сервер

Language