데이터센터 6곳 전체 정상

암호화폐 결제 · 신원 확인 없음 · 5분 미만 안에 root 권한

중대 해결됨

Core switch line-card failure in REY, row B

네트워크 — 트랜싯 및 피어링 — REY · 대역 외 관리 — REY

타임라인

  1. 해결됨

    Every machine in row B has been reachable since 22:22 UTC. Duration of the outage: 54 minutes. The failed card is being replaced under an existing maintenance window; the replacement does not require another interruption. Affected machines receive the SLA extension automatically.

  2. 모니터링 중

    All 14 affected ports are up on the surviving card. We are checking each machine individually before closing this.

  3. 원인 확인

    A line card in one of the two core switches in REY failed. Row B was dual-homed, but the failover on 14 ports did not complete because the standby links were still training. We are forcing those ports over to the surviving card.

  4. 조사 중

    Machines in row B of REY lost network connectivity at 21:28 UTC. Rows outside B are unaffected. Engineers are on the floor.

사후 검토는 해결 후 5일 이내에 이곳에 게시됩니다.

로그인

콘솔, 청구서, 대역 외 접근.

계정이 없으십니까?

별도의 회원가입은 없습니다. 첫 주문을 진행하는 동안 계정이 만들어집니다 — 결제 단계에서 이메일과 비밀번호를 직접 정하시고, 머신이 준비될 때쯤이면 콘솔도 이미 열려 있습니다.

서버 구성하기

Language