Core switch line-card failure in REY, row B
ネットワーク — トランジット・ピアリング — REY · アウトオブバンド管理 — REY
タイムライン
-
解決済み
Every machine in row B has been reachable since 22:22 UTC. Duration of the outage: 54 minutes. The failed card is being replaced under an existing maintenance window; the replacement does not require another interruption. Affected machines receive the SLA extension automatically.
-
監視中
All 14 affected ports are up on the surviving card. We are checking each machine individually before closing this.
-
原因特定
A line card in one of the two core switches in REY failed. Row B was dual-homed, but the failover on 14 ports did not complete because the standby links were still training. We are forcing those ports over to the surviving card.
-
調査中
Machines in row B of REY lost network connectivity at 21:28 UTC. Rows outside B are unaffected. Engineers are on the floor.
事後レビューは、解決から5日以内にここに公開されます。
時刻はお使いのタイムゾーン()で表示されます。