BMC sensor read errors on L4 nodes in AMS

Gestione fuori banda — AMS

Cronologia

  1. Risolto

    Sensor data is complete for every node. Duration: 1 h 4 min. The fixed firmware is being rolled out during regular maintenance; no host reboot is required.

  2. In osservazione

    All 9 BMCs have been reset and report cleanly. Watching for recurrence.

  3. Causa individuata

    A BMC firmware version on 9 nodes has a bug in its sensor polling that surfaces after a long uptime. Resetting the BMC clears it without touching the host; we are doing that node by node.

  4. In analisi

    The BMCs on some L4 nodes in AMS are returning sensor read errors since 08:42 UTC. Power and temperature readings in the customer area are missing for those machines. The machines themselves are unaffected.