Серьёзный Устранено

Core switch line-card failure in ZRH, row C

Сеть — транзит и пиринг — ZRH · Внеполосное управление — ZRH

Хронология

  1. Устранено

    Every machine in row C has been reachable since 07:12 UTC. Duration of the outage: 50 minutes. The failed card is being replaced under an existing maintenance window; the replacement does not require another interruption. Affected machines receive the SLA extension automatically.

  2. Наблюдение

    All 13 affected ports are up on the surviving card. We are checking each machine individually before closing this.

  3. Причина установлена

    A line card in one of the two core switches in ZRH failed. Row C was dual-homed, but the failover on 13 ports did not complete because the standby links were still training. We are forcing those ports over to the surviving card.

  4. Идёт расследование

    Machines in row C of ZRH lost network connectivity at 06:22 UTC. Rows outside C are unaffected. Engineers are on the floor.