데이터센터 6곳 전체 정상

암호화폐 결제 · 신원 확인 없음 · 5분 미만 안에 root 권한

중대 해결됨

Core switch line-card failure in ZRH, row C

네트워크 — 트랜싯 및 피어링 — ZRH · 대역 외 관리 — ZRH

타임라인

  1. 해결됨

    Every machine in row C has been reachable since 07:12 UTC. Duration of the outage: 50 minutes. The failed card is being replaced under an existing maintenance window; the replacement does not require another interruption. Affected machines receive the SLA extension automatically.

  2. 모니터링 중

    All 13 affected ports are up on the surviving card. We are checking each machine individually before closing this.

  3. 원인 확인

    A line card in one of the two core switches in ZRH failed. Row C was dual-homed, but the failover on 13 ports did not complete because the standby links were still training. We are forcing those ports over to the surviving card.

  4. 조사 중

    Machines in row C of ZRH lost network connectivity at 06:22 UTC. Rows outside C are unaffected. Engineers are on the floor.

사후 검토는 해결 후 5일 이내에 이곳에 게시됩니다.