Mineur Résolu

Packet loss on the Arelion uplink in STO

Réseau — transit et peering — STO

Chronologie

  1. Résolu

    The Arelion uplink in STO has been clean for 7 minutes with the session restored. Total duration of the degradation: 37 minutes. No machine lost connectivity; some traffic saw higher latency during the detour.

  2. Sous surveillance

    Arelion reports the card replaced. We have re-enabled the session and are watching error counters before calling this resolved.

  3. Cause identifiée

    Arelion has confirmed a faulty line card on their side of the STO handover. We have withdrawn our prefixes from that session, and all traffic is leaving through GlobalConnect and STHIX for now. Loss has cleared; latency to some destinations is 3–6 ms higher while the detour is in place.

  4. Investigation en cours

    We are investigating packet loss of around 2% towards a subset of destinations from STO. Alerts fired at 12:04 UTC on the Arelion uplink; the GlobalConnect uplink and the STHIX peering are clean. Machines remain reachable.