L’ensemble des 6 centres de données opérationnels

Payé en crypto · Sans vérification d’identité · Accès root en moins de 5 minutes

Mineur Résolu

Packet loss on the Cogent uplink in AMS

Réseau — transit et peering — AMS

Chronologie

  1. Résolu

    The Cogent uplink in AMS has been clean for 23 minutes with the session restored. Total duration of the degradation: 1 h 35 min. No machine lost connectivity; some traffic saw higher latency during the detour.

  2. Sous surveillance

    Cogent reports the card replaced. We have re-enabled the session and are watching error counters before calling this resolved.

  3. Cause identifiée

    Cogent has confirmed a faulty line card on their side of the AMS handover. We have withdrawn our prefixes from that session, and all traffic is leaving through Lumen and NL-ix for now. Loss has cleared; latency to some destinations is 3–6 ms higher while the detour is in place.

  4. Investigation en cours

    We are investigating packet loss of around 5% towards a subset of destinations from AMS. Alerts fired at 05:05 UTC on the Cogent uplink; the Lumen uplink and the NL-ix peering are clean. Machines remain reachable.