Suboptimal routing for a subset of prefixes from STO
Network — transit & peering — STO
Timeline
-
Resolved
Routing is back to normal from every probe location. Duration: 13 minutes. Latency on the affected path was up to 15 ms above normal; no connectivity was lost.
-
Identified
A transit provider two hops away leaked a more specific route for one of our /24s. We have announced the same more specific ourselves so that it wins on the shortest path, and we have asked GlobalConnect to filter the leak upstream.
-
Investigating
A subset of our STO prefixes is being reached over an unusually long path from Taiwan. We see it in our external probes; users in other regions are not affected.