Amsterdam
Netherlands
Bandwidth is where hosting pages are vaguest, so this one is specific: what each port is, what it costs when you saturate it, who we buy transit from, and what we do not offer.
The port is sized with the chassis, because a node that can saturate a card can saturate a link. Every port is unmetered in both directions: there is no included volume, no overage tier and nothing to watch on a graph.
| Node | Port | Monthly traffic | Upgrade | Cost of the upgrade |
|---|---|---|---|---|
| 1 × GPU | 1 Gbit/s | Unmetered | 10 Gbit/s | $49/mo |
| 2 × GPU | 2 Gbit/s | Unmetered | 10 Gbit/s | $49/mo |
| 4 × GPU | 10 Gbit/s | Unmetered | Already 10 Gbit/s or above | — |
| 8 × GPU | 25 Gbit/s | Unmetered | Already 10 Gbit/s or above | — |
| 10 × GPU | 25 Gbit/s | Unmetered | Already 10 Gbit/s or above | — |
Unmetered means what it says: you may hold the port at line rate for the whole month. We reserve the right to talk to you about it only if a single machine starts degrading the shared uplink for everybody else in the suite — and that conversation has happened twice in five years, both times about a misconfigured mirror.
Every site buys from at least two independent carriers and sits on the local internet exchange. A carrier failure is a re-route, not an outage — which is the only reason we are willing to write 99.9% on a contract.
| Data centre | Internet exchange | Transit carriers | Uplink |
|---|---|---|---|
| Amsterdam | AMS-IX, NL-ix | Cogent, Arelion, Lumen | 2 × 100 Gbit/s |
| Stockholm | Netnod, STHIX | Arelion, GlobalConnect | 2 × 100 Gbit/s |
| Zürich | SwissIX, CIXP | Init7, Cogent | 2 × 100 Gbit/s |
| Reykjavík | RIX Reykjavík | Farice, Síminn | 2 × 100 Gbit/s |
| Montréal | QIX Montréal | Cogent, Zayo | 2 × 100 Gbit/s |
| Singapore | SGIX, Equinix Singapore | Arelion, Singtel | 2 × 100 Gbit/s |
Volumetric filtering is on from the moment the machine is delivered. It is not an option, it is not a tier, and it does not appear on the invoice.
Scrubbing at the edge of each site, in front of our own routers. Detection is automatic on rate and signature; nothing waits for a human.
Under ten seconds from the first anomalous packet to filtered traffic, up to the site's full transit capacity. Legitimate sessions are not reset.
Some hosts answer an attack by dropping your IP for 24 hours. We filter it. Your machine stays reachable, which is the entire point of paying for filtering.
Inside a node, what connects the cards to each other decides whether a large model is fast or merely possible. This is the part of the specification we are asked about most, and the part most listings leave out.
| Form factor | Cards | Between GPUs | Practical effect |
|---|---|---|---|
| SXM on an HGX board | A100 SXM4 80 GB, H100 SXM5 80 GB, H200 SXM5 141 GB, B200 SXM6 180 GB | NVLink via NVSwitch | Tensor parallelism across the whole board without the interconnect becoming the bottleneck. |
| PCIe cards | L4 24 GB, RTX 4090 24 GB, RTX 5090 32 GB, RTX A6000 48 GB, L40S 48 GB, A100 PCIe 40 GB… | PCIe Gen4 ×16 or Gen5 ×16 | Fine for pipeline parallelism, batch inference and one-model-per-card serving. Slower than NVLink for tensor parallelism across many cards. |
If you are unsure which of the two your workload needs: a model that fits on one card never needs NVLink, and a model split across four or more cards almost always benefits from it. The fit checker in the configurator tells you which case you are in before you pay.
Measured from our own routers to the named cities, as a round trip, over thirty days. They are medians, not best cases.
Netherlands
Sweden
Switzerland
Iceland
Canada
Singapore
Stated here rather than discovered after payment. If one of these is a requirement, we are the wrong provider and it is cheaper for both of us to know now.
Multi-node InfiniBand. NVLink connects the cards inside one node. We do not sell a fabric between nodes, so a job that needs 32 GPUs in one training run is not something we can serve.
BGP sessions or bring-your-own-IP. We announce our own space only. There is no way to advertise your prefix from our routers.
Layer-2 links between data centres. A private VLAN joins your machines within one site. Between sites, you build the tunnel yourself.
Committed transit or a private uplink. The port is unmetered and shared upstream. We will not sign a dedicated-capacity contract on top of it.
Open SMTP on delivery. Port 25 outbound is closed until you ask, for the reason given above.
An anonymity network. Filtering protects your machine from attack. It is not a proxy, it does not hide where your traffic goes, and we do not pretend otherwise.
There is no networking tier to choose. Pick the GPU, pick the site, and the port comes with the chassis.